ISL5585
DC Verification
When the internal signal path is provided, DC current will
flow from Tip to Ring. The DC current will force DET low,
indicating the presence of loop current. In addition, the ALM
output will also go low. This does not indicate a thermal
alarm condition. Rather, proper logic operation is verified in
the event of a thermal shutdown. In addition to verifying
device functionality, toggling the logic outputs verifies the
interface to the system controller.
Power Denial
Overview
The power denial mode (111) will shutdown the entire device
except for the logic interface. Loop supervision is not
provided. This mode may be used as a sleep mode or to
shut down in the presence of a persistent thermal alarm.
Switching between high and low battery will have no effect
during power denial.
AC Verification
The entire AC loop of the device is active during the forward
loop back mode. Therefore a 4-wire to 4-wire level test
capability is provided. Depending on the transhybrid balance
implementation, test coverage is provided by a one or two
step process.
System architectures which cannot disable the transhybrid
function would require a two step process. The first step
would be to send a test tone to the device while on hook and
not in forward loop back mode. The return signal would be
the test level times the gain R
F
/R
A
of the transhybrid
amplifier. Since the device would not be terminated,
cancellation would not occur. The second step would be to
program the device to FLB and resend the test tone. The
return signal would be much lower in amplitude than the first
step, indicating the device was active and the internal
termination attenuated the return signal. System
architectures which disable the transhybrid function would
achieve test coverage with a signal step. Once the
transhybrid function is disable, program the device for FLB
and send the test tone. The return signal level is determined
by the 4-wire to 4-wire gain of the device.
Functionality
During power denial, both the Tip and Ring amplifiers are
disabled, representing high impedances. The voltages at
both outputs are near ground.
Thermal Shutdown
In the event the safe die temperature is exceeded, the ALM
output will go low and DET will go high and the part will
automatically shut down. When the device cools, ALM will
go high and DET will reflect the loop status. If the thermal
fault persists, ALM will go low again and the part will shut
down. Programming power denial will permanently
shutdown the device and stop the self cooling cycling.
Battery Switching
Overview
The integrated battery switch selects between the high
battery and low battery. The battery switch is controlled
with the logic input BSEL. When BSEL is a logic high, the
high battery is selected and when a logic low, the low
battery is selected. All operating modes of the device will
operate from high or low battery except forward loop back,
which requires low battery for thermal reasons.
Tip Open
Overview
The tip open mode (110) is intended for compatibility for
PBX type interfaces. Used during idle line conditions, the
device does not provide transmission. Loop supervision is
provided by either the switch hook detector (E0 = 1) or the
ground key detector (E0 = 0). The ground key detector will
be used in most applications. The device may be operated
from either high or low battery.
Functionality
The logic control is independent of the operating mode
decode. Independent logic control provides the most
flexibility and will support all application configurations.
When changing device operating states, battery switching
should occur simultaneously with or prior to changing the
operating mode. In most cases, this will minimize overall
power dissipation and prevent glitches on the DET output.
The only external component required to support the battery
switch is a diode in series with the V
BH
supply lead. In the
event that high battery is removed, the diode allows the
device to transition to low battery operation.
Functionality
During tip open operation, the Tip switch is disabled and the
Ring switch is enabled. The minimum Tip impedance is
30k鈩? The only active path through the device will be the
Ring switch.
In keeping with the MTU characteristics of the device, Ring
will not exceed -56V when operating from the high battery.
Though MTU does not apply to tip open, safety requirements
are satisfied.
Low Battery Operation
All off hook operating conditions should use the low battery.
The prime benefit will be reduced power dissipation. The
typical low battery for the device is -24V. However this may
be increased to support longer loop lengths or high loop
current requirements. Standby conditions may also operate
from the low battery if MTU compliance is not required,
further reducing standby power dissipation.
18

ISL5585 PDF文件相關(guān)型號(hào)

ISL5585 XXX,ISL5585AIMZ,ISL5585BIMZ,ISL5585CIMZ,ISL5585DIMZ,ISL5585ECMZ,ISL5585ECRZ,ISL5585FCRZ,ISL5585GCMZ

ISL5585相關(guān)型號(hào)PDF文件下載

您可能感興趣的PDF文件資料

熱門(mén)IC型號(hào)推薦

掃碼下載APP,
一鍵連接廣大的電子世界。

在線人工客服

買家服務(wù):
賣家服務(wù):
技術(shù)客服:

0571-85317607

網(wǎng)站技術(shù)支持

13606545031

客服在線時(shí)間周一至周五
9:00-17:30

關(guān)注官方微信號(hào),
第一時(shí)間獲取資訊。

建議反饋
返回頂部

建議反饋

聯(lián)系人:

聯(lián)系方式:

按住滑塊,拖拽到最右邊
>>
感謝您向阿庫(kù)提出的寶貴意見(jiàn),您的參與是維庫(kù)提升服務(wù)的動(dòng)力!意見(jiàn)一經(jīng)采納,將有感恩紅包奉上哦!