鈮?/div>
0.2V
Note :
1. Measured with outputs open.
2. Refresh period is 32ms.
AC INPUT OPERATING CONDITIONS
Recommended operating conditions(Voltage referenced to V
SS
=0V, V
DD
=2.5V+ 5%, V
DDQ
=2.5V+ 5%,T
A
=0 to 65擄C)
Parameter
Input High (Logic 1) Voltage; DQ
Input Low (Logic 0) Voltage; DQ
Clock Input Differential Voltage; CK and CK
Clock Input Crossing Point Voltage; CK and CK
Symbol
V
IH
V
IL
V
ID
V
IX
Min
V
REF
+0.35
-
0.7
0.5*V
DDQ
-0.2
Typ
-
-
-
-
Max
-
V
REF
-0.35
V
DDQ
+0.6
0.5*V
DDQ
+0.2
Unit
V
V
V
V
Note
1
2
Note :
1. V
ID
is the magnitude of the difference between the input level on CK and the input level on CK
2. The value of V
IX
is expected to equal 0.5*V
DDQ
of the transmitting device and must track variations in the DC level of the same
3. For the K4D261638E-TC2A, VDD & VDDQ = 2.8V+0.1V.
- 11 -