= 10K鈩?/div>
Min.
Typ.
Max.
5
5
150
150
0.9
0.9
Unit
碌s
碌s
碌s
碌s
碌s
碌s
LINE TRANSIENT IMMUNITY
(Considering the following cases: Powered ON, Powered OFF-Low im-
pedance power supply and Powered OFF-High impedance supply).
ESD
EOS
Elettrostatic Discharge
Electrical Overstress
Tested per MIL-STD-883
(see note 6)
Transient pulse both polarities
for 100碌s (see note 7)
2
50
KV
V
Note 3:
The output leakage is measured under the following conditions:
a) The Driver tristated
b) Power supply OFF, and the power pins shorted to Ground
c) Power supply OFF. Impedances between power pins open and power pins shorted to Ground.
Note 4:
The output waveform should not show any signs of oscillations under any load variation between o.1VVss and 0.9Vss. The oscillation
allowed when V
SS
< 0.1V
SS
and V
ss
>0.9V
ss
shall be 10% of V
ss
.
Note 5:
t
fc1
thru t
rc4
shall be within
鹵20%
of t
rc1
thru t
rc4
respectively.
Note 6:
All pins are required to withstand parameter.
Note 7:
Output pins are required to withstand fig.5 without any degradation to the circuit.
TEST CIRCUIT
4/9