M29W160FT, M29W160FB, M29W320FT, M29W320FB
Maximum rating
6
Maximum rating
Stressing the device above the rating listed in
Table 8: Absolute maximum ratings
may
cause permanent damage to the device. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability. These are stress ratings only and
operation of the device at these or any other conditions above those indicated in the
operating sections of this specification is not implied. Refer also to the Numonyx SURE
Program and other relevant quality documents.
Table 8.
Symbol
T
A
T
BIAS
T
STG
V
IO
V
CC
V
ID
Absolute maximum ratings
Parameter
Ambient temperature grade 3
Temperature under bias
Storage temperature
Input or output voltage
(1)(2)
Supply voltage
Identification voltage
Min
鈥?0
鈥?0
鈥?5
鈥?.6
鈥?.6
鈥?.6
Max
125
125
150
V
CC
+0.6
4
13.5
Unit
擄C
擄C
擄C
V
V
V
1. Minimum voltage may undershoot to 鈥? V during transition and for less than 20 ns during transitions.
2. Maximum voltage may overshoot to V
CC
+2 V during transition and for less than 20 ns during transitions.