W681310
SYMBOL
1/T
MCK
DESCRIPTION
Master Clock Frequency
MIN
---
TYP
256
512
1536
1544
2048
2560
4096
4800
MAX
---
UNIT
kHz
T
MCKH
/
T
MCK
T
MCKH
T
MCKL
T
FTRHM
T
FTRSM
T
RISE
T
FALL
MCLK Duty
Operation
Cycle
for
256
kHz
45%
50
50
50
50
---
---
---
---
---
---
---
---
55%
---
---
---
---
50
50
ns
ns
ns
ns
ns
ns
Minimum Pulse Width HIGH for
MCLK(512 kHz or Higher)
Minimum Pulse Width LOW for MCLK
(512 kHz or Higher)
MCLK falling Edge to FST Rising Edge
Hold Time
FST Rising Edge to MCLK Falling edge
Setup Time
Rise Time for All Digital Signals
Fall Time for
All Digital Signals
Table 8.5 General PCM Timing Parameters
- 19 -
Publication Release Date: September 2005
Revision B13