A power-on reset pulse is generated by a V
DD
rise across the default BOT voltage level
(1.7 V). A brown-out reset pulse is generated when V
DD
falls below the brown-out volt-
age threshold. Two values for the brown-out voltage threshold are programmable via
the BOT-bit in the SC-register. When the controller runs in the upper supply voltage
range with a high system clock frequency, the high threshold must be used. When it
runs with a lower system clock frequency, the low threshold and a wider supply voltage
range may be chosen. For further details, see the electrical specification and the SC-
register description for BOT programming.
Figure 16.
Brown-out Detection
V
DD
2.0 V
1.7 V
td
CPU
Reset
BOT = '1'
td
CPU
Reset
BOT = '0'
t = 1.5 ms (typically)
d
td
t
BOT = 1, low brown-out voltage threshold 1.7 V (is reset value).
BOT = 0, high brown-out voltage threshold 2.0 V.
Watchdog Reset
The watchdog鈥檚 function can be enabled at the WDC-register and triggers a reset with
every watchdog counter overflow. To suppress the watchdog reset, the watchdog
counter must be regularly reset by reading the watchdog register address (CWD). The
CPU reacts in exactly the same manner as a reset stimulus from any of the above
sources.
The external input clock supervisor function can be enabled if the external input clock is
selected within the CM- and SC-registers of the clock module. The CPU reacts in
exactly the same manner as a reset stimulus from any of the above sources.
The voltage monitor consists of a comparator with internal voltage reference. It is used
to supervise the supply voltage or an external voltage at the VMI-pin. The comparator
for the supply voltage has three internal programmable thresholds one lower threshold
(2.2 V), one middle threshold (2.6 V) and one higher threshold (3.0 V). For external volt-
ages at the VMI-pin, the comparator threshold is set to V
BG
= 1.3 V. The VMS-bit
indicates if the supervised voltage is below (VMS = 0) or above (VMS = 1) this thresh-
old. An interrupt can be generated when the VMS-bit is set or reset to detect a rising or
falling slope. A voltage monitor interrupt (INT7) is enabled when the interrupt mask bit
(VIM) is reset in the VMC-register.
External Clock Supervisor
Voltage Monitor
22
T48C862-R8
4590B鈥?BMCU鈥?2/03

T48C862-R8相關型號PDF文件下載

您可能感興趣的PDF文件資料

熱門IC型號推薦

掃碼下載APP,
一鍵連接廣大的電子世界。

在線人工客服

買家服務:
賣家服務:
技術客服:

0571-85317607

網站技術支持

13606545031

客服在線時間周一至周五
9:00-17:30

關注官方微信號,
第一時間獲取資訊。

建議反饋
返回頂部

建議反饋

聯(lián)系人:

聯(lián)系方式:

按住滑塊,拖拽到最右邊
>>
感謝您向阿庫提出的寶貴意見,您的參與是維庫提升服務的動力!意見一經采納,將有感恩紅包奉上哦!